A porous PTFE membrane is impregnated with a water-immiscible organic solvent, giving the supported liquid membrane.
2021/1/5 · The hydrophobic membrane is PTFE with PP backing. In the pilot investigation, the feed flow rate, condenser inlet, and outlet temperatures were kept at 300 L/h, 25 C, and 80 C, respectively. The membrane flux decreased from 2.1 to 0.7 LMH when the feed
that can contaminate the sample manager. (PTFE is recommended.) c. Use Waters-brand wellplates. Be aware that other brands may leach plasticizers (e.g., diisooctylphthalates). d. Foil-lined plate covers are acceptable as long as the aluminum does not
2015/12/1 · More recently membrane distillation has been also used in membrane bioreactor configuration (MDBR) for the treatment of industrial and municipal used waters, in order to retain effectively small size and persistent contaminants (Phattaranawik et al. 2008).
LMH when five pieces of membrane were studied. In direct contact membrane distillation, called MD in this study, a PTFE 0.2µm membrane (Sterlitech, USA) was used. Pure water was used at the permeate side so the temperature difference was 60 C feed/20
wwPTFE (Water Wettable PTFE) Membrane Disc Filters, Pall Laboratory Supplier: Pall Laboratory Description: Next generation of universal hydrophilic PTFE membrane with maximum chemical compatibility when filtering both aqueous solutions and aggressive solven
We design and sell a complete line of DI and RO/DI hybrid water processors. So we naturally get a lot of request for information about DI material compatibility. The table below lists the most common interactions. Bear in mind that anything metallic will yield a small amount of metal back into the water until passivated, and then still smaller
2020/11/1 · The pristine NESMD membrane had a contact angle of 0.0 on the CB-coated PP feed-side and 137.8 on the PTFE permeate-side, validating the membrane as a hydrophilic/hydrophobic composite. After the NESMD of PW1, the membrane contact angle of the PTFE-permeate side of the membrane remained static whereas the CB-PP feed side increased from 0.0° to 66.4°
2019/7/15 · A hydrophobic, microporous membrane from Sterlitech Corporation (WA, US A) was used in the MD tests. The membrane is made of an unsupported thin polytetrafluoroethylene (PTFE) layer, featuring a nominal pore size and thickness of 0.45 μm and 25 ± 6 μm
2017/5/9 · Thus, for example, the porous PTFE membrane can be used to remove trace metals such as Li, Na, K (and other Group 1 metals); Mg, Ca (and other Group 2 metals); Al (and other Group 3 metals), Pb (and other Group 4 metals), Sb, Bi (and other Group 5