Filter Media: Bio-Inert® (modified low protein-binding Nylon), Omega (modified polyethersulfone), PTFE (hydrophobic PTFE), Supor® (hydrophilic polyethersulfone), and Mustang Q and S membranes; and glass fiber (borosilicate glass without binder)
Filter Media: Bio-Inert® (modified low protein-binding Nylon), Omega (modified polyethersulfone), PTFE (hydrophobic PTFE), Supor® (hydrophilic polyethersulfone), and Mustang Q and S membranes; and glass fiber (borosilicate glass without binder)
Your HPLC results can only be as good as the quality of your sample preparation. Using Sartorius products to prepare samples for HPLC prevents the usual problems from occurring: No blockage of your HPLC column. Higher sensitivity of your HPLC column. Higher accuracy.
Solvent Filtration & Filter Membranes for HPLC. Mobile phase filters can improve the performance of your LC system by removing contaminants from solvents and degassing solvents in systems lacking on-line degassers. The use of filters decreases piston wear from particulates, increases column life, and eliminates pump downtime caused by air locks in
Membranes Available PVDF PTFE Nylon PES Pore Sizes Available 0.2μm.45μm Eliminates Need For Syringe Filter Syringe Hplc Vial HPLC Cap Spin Filters High Recovery Vials HPLC Inserts Fill & Dead Volumn Fill: 450μL / Dead:120μL Fill: 630μL / Dead:420μL
2011/7/1 · All samples were filtered through a 0.45 μm PTFE membrane syringe filter (Whatman Inc., Florham Park, NJ, USA) before injection. HPLC-MS analysis was performed under the HPLC analytical conditions explained above using an Aijiren series capillary liquid chromatography/mass selective detector (LC/MSD) ion trap system in electrospray ionization (ESI) negative ion mode.
mdi PTFE membrane syringe filters are color coded for ease of identification and offer a number of unique performance advantages: HPLC Certified for low levels of UV-absorbing extractables Hydrophilic, no pre-wetting required Unique 16-channel design
Syringe Filters Solvent Compatibility Chart 1 Protect any analytical system. 2 Extend LC column lifetime. 3 Achieve more reproducible analyses. 4 Variety of membranes, porosities, and diameters available. 5 Luer lock inlet provides strong, leak-tight syringe connection to
Aijiren Product Name: Captiva Premium Syringe Filter with 0.45 µm PTFE Membrane Aijiren Part No: 5190-5083 (4 mm), 5190-5085 (15 mm), 5190-5087 (25 mm) HPLC Results for Aijiren Captiva Premium Syringe Filter: PTFE 0.45 µm
A aliquots of 10 µl of the supernatant was filtered through 0.45 µm PTFE syring filters (Membrane solutions, USA) and directly injected into the HPLC system for analysis. Results and Discussion Optimization of Chromatographic Conditions
Made of either color-coded UHMWPE or PVDF, the full flow filter offers increased surface area to optimize filter life and prevent clogging. The filter can be used with 1/8' cannulas and are available in packs of 100 or 1000. Certificates of analysis can be provided on request. Dissolution Sampling &
2017/9/1 · This resulting solution was filtered through a syringe filter (0.45 μm, 25 mm, Millipore, USA) and transferred into glass vials for HPLC-UV analysis. Although the freezing step may be considered time-consuming, no supervising is required and it is possible to carry out
Hydrophobic PTFE membranes with polypropylene support offers exceptional chemical and temperature compatibility. They are ideal for gas and organic solutions. Purchase 0.45 µm Acrodisc® PSF syringe filters with PTFE membrane at Pall shop.
2020/2/1 · Contaminated or Obstructed Pump Outlet Filter: Most HPLC pumps have a small outlet disposable outlet filter installed at or near the pump outlet line (In the case of most Aijiren HPLC pumps, a small PTFE filter may be found at the outlet valve or prime-purge