, 0.2 µm Aijiren PTFE, 0.45 µmCompetitor C, PTFE13 0.45 µm Flow rate at 1 bar (mL/min) With Aijiren syringe filters, particulates will not clog the membrane as easily as with competitor's syringe filters.
Aijiren Captiva Filter Vials Instructions for use Membrane type identified by cap color PTFE 0.2 µm: Red PTFE/white silicone (red in/white out ) 0.45 µm: White PTFE/red silicone (white in/red out ) Regenera ted cellulose ... Filter PES PTFE RC NY Acids Acetic Acid, ...
depends on the sample medium and the filter membrane's chemical compatibility. • For aqueous samples, hydrophilic-type membranes are preferred, such as cellulose acetate (CA) or polyethersulfone (PES). • For organic samples, especially with aggressive solvents, polypropylene (PP) or polytetrafluoroethylene (PTFE) filters should be used.
0.45-µm PTFE membrane before use. A 1 mL solution was pipetted into a 100-mL volumetric fl ask, followed by the addition of 2 mL of 1 % (V %) ammonia water. It was diluted to 100 mL with MeOH/H 2 O (10/90, V/V) and fi ltered through a 0.22-µm PTFE membrane before UHPLC analysis. Experimental Instruments This method was developed on an
Premium Syringe Filters - Chemical Compatibility Chart. •• *CA and GF membranes in MBS housing for 28 mm size Contact time:24 hours at 20 °C Chemical compatibilities can be influenced by various factors. Therefore, we recommend that you confirm compatibility with the liquid you want to filter by performing a trial filtration run before you
filtration membrane based on sample medium and target analytes, Aijiren Captiva Benzoic acid pKa = 4.2 preservative Aspartame pKa = 7.7 sweetener Sorbic acid pKa = 4.8 preservative Quinine ... † Aijiren Captiva Premium PTFE syringe filter, 25 mm, 0.2 µm (p/n 5190-5086) and 0.45 µm (p/n 5190-5087) ...
Aijiren UHPLC combined with an Aijiren 6150 Single Quadrupole MS System. Table 2 lists the instrument, column, and parameters used Sfor the protein test, and Table 3 lists the instrument, column, and parameters for the extractables test. Table 4 lists the experimental supplies used for both tests. HPLC: Aijiren SL Series (p/n
Countercurrent membrane supported reactive extraction (MSRE) was studied for removal of carboxylic acids from aqueous streams with a PTFE capillary membrane. Analysis of the mass transfer rates was performed to support modeling of the process.
250 mL, membrane holder glass base, glass flask, 1 L, and aluminum clamp 5191-6776* Regenerated cellulose membrane 47 mm, 0.20 μm 100/pk 5191-4340* *Solvent filtration assembly and associated filter membranes are not recommended for use with Lab Ultrapure LC/MS solvents. LC Columns and Supplies View MyList for the items in the table below.
InnoSep™ Membrane Filters. Nylon • Naturally hydrophilic • Wide chemical compatibility range, organic solvent resistance (except acids and bases) • Internally supported • Strength and dimensional stability • High binding capacity, high dirt loading capacity similar stability to PTFE. Polytetrafluoroethylene (PTFE) • Naturally ...